CGDWH - LOCQUIC PRIMER N 7649, 19269

  • MSDS: CGDWH
  • Manufacturer: LOCTITE CORP
  • Product Name: LOCQUIC PRIMER N 7649, 19269
  • National Stock Number: 8030-01-441-6478
Product Identification

Product ID:LOCQUIC PRIMER N 7649, 19269
MSDS Date:01/22/1996
FSC:8030
NIIN:01-441-6478
MSDS Number: CGDWH

Responsible Party
LOCTITE CORP
1001 TROUT BROOK CROSSING
ROCKY HILL, CT 06067-3910
US

Emergency Phone: 860-571-5100

Info Phone: 860-571-5100

Preparer: STEPHEN REPETTO

Cage: 7K128

Contractor
LOCTITE CORPORATION
ROCKY HILL, CT 06067-3910 US

Telephone: 860-571-5100

Cage: 05972

Ingredients

ACETONE (SARA 313) (CERCLA)

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: 95-100%

OSHA PEL 1000 PPM

ACGIH TLV: 750 PPM/1000 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


HEXANOIC ACID, 2-ETHYL-; (2-ETHYLHEXANOIC ACID)

CAS: 149-57-5

RTECS: MO7700000

Fraction By Weight: 0.1-1%

OSHA PEL N/K

ACGIH TLV: N/K


HEXANOIC ACID, 2-ETHYL-, COPPER SALT; (ORGANO-COPPER

CAS: 22221-10-9

RTECS: MO7708000

Fraction By Weight: 0.1-1%

OSHA PEL N/K

ACGIH TLV: N/K


TRIALKYLAMMONIUM CARBOXYLATE

CAS: 58823-74-8

Fraction By Weight: 0.1-1%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: HARMFUL IF INHALED OR
SWALLOWED. POSSIBLE EYE AND RESPIRATORY IRRITATION. NARCOTIC AT
HIGH CONCENTRATIONS. PROLONGED INHALATION MAY CAUSE HEADACHE.
MODERATELY TOXIC BY INGESTION. LIQUID MAY DEF AT SKIN.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:VAPORS MAY IRRITATE EYES, NOSE AND THROAT.
LIQUID IS AN EYE IRRITANT AND MAY IRRITATE SKIN.
Medical Cond Aggravated by Exposure:NONE KNOWN.

First Aid

First Aid:INGESTION: GIVE WATER TO DILUTE. DO NOT INDUCE VOMITING. KEEP
INDIVIDUAL CALM. OBTAIN MEDICAL ATTENTION. INHALATION: REMOVE TO
FRESH AIR. IF SYMPTOMS PERSIST, OBTAIN MEDICAL ATTENTION. SKIN:
WASH WITH SOAP AND WATER. EYES: FLUSH WITH WATERFOR AT LEAST 15
MINUTES. OBTAIN MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:TCC
Flash Point:-4F,-20C
Lower Limits:2.6%
Upper Limits:13%
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:AVOID FLAME AND SPARKS. MAINTAIN ADEQUATE
VENTILATION. SOAK UP IN AN INERT ABSORBENT AND STORE IN A CLOSED
CONTAINER UNTIL DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AWAY FROM FLAME AND SPARKS. KEEP
BELOW 100F. AVOID PROLONGED BREATHING OF FUMES. AVOID SKIN OR EYE
CONTACT.
Other Precautions:DO NOT USE NEAR HEAT, SPARKS, OR OPEN FLAME. CONTACT
LOCTITE CUSTOMER SERVICE 1-800-243-4874 FOR SHELF LIFE INFORMATION.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:SUFFICIENT TO MAINTAIN VAPOR CONCENTRATION BELOW TLV.
Protective Gloves:RUBBER OR PLASTIC GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:F2
Boiling Pt:B.P. Text:133F,56C
Vapor Pres:172 @ 68F
Spec Gravity:0.7936
VOC Pounds/Gallon:12
Evaporation Rate & Reference:1.9 (ETHER=1)
Solubility in Water:MISCIBLE
Appearance and Odor:GREEN LIQUID; ACETONE ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, PEROXIDES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:IRRITATING ORGANIC VAPORS.

Disposal

Waste Disposal Methods:INCINERATE FOLLOWING EPA AND LOCAL REGULATIONS.
D001 - HAZARDOUS WASTE PER 40 CFR 261.21. DISPOSE OF IN ACCORDANCE
WITH LOCAL, STATE AND FEDERAL REGULATIONS .

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their